DSR Commercial Integrated Receiver/Decoder. SPECIFICATION ShEET. A Multi-Format Digital Satellite Receiver for Cable Programmers and Operators. DSR / DSR Operator Guide • Desenchufe el aparato durante tormentas eléctricas o cuando no lo utilice durante largos períodos de tiempo. • Remita. SPECIFICATION sheeT DSR Commercial Integrated Receiver/Decoder A Multi-Format Digital Satellite Receiver for Cable Programmers and Operators.

Author: Shaktill Dougore
Country: Lithuania
Language: English (Spanish)
Genre: Science
Published (Last): 26 October 2004
Pages: 340
PDF File Size: 7.45 Mb
ePub File Size: 5.99 Mb
ISBN: 130-8-69796-445-8
Downloads: 87912
Price: Free* [*Free Regsitration Required]
Uploader: Gumi

No part of this publication may be reproduced in any form or by any means or used to make any derivative work such as translation, transformation, or adaptation without written permission from ARRIS Enterprises, Inc.

ARRIS reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products.

ARRIS disclaims proprietary interest in the marks and names of others. ARRIS provides this guide without warranty of any kind, implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.

ARRIS may make improvements or changes in the product s described in this manual at any time. All other trademarks are the property of their respective owners. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong.

The wide blade or the third prong is provided for your safety.

DSR-4460 – DSR-4460 COMMERCIAL INTEGRATED RECEIVER/DECODER

If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the apparatus, the apparatus has been exposed dsf rain or moisture, does not operate normally, or has been dropped.

Damage Requiring Service Unplug this equipment from the power source, and contact a qualified service provider if any of the following situations occurs: Service Do not dsg to service this product yourself. 44460 a qualified service provider for all service. La instalacion debe de hacerse acorde con las instrucciones del manufacturador. No anule el proposito de seguridad del enchufe polarizado o la coneccion a tierra.

El enchufe polarizado tiene dos terminals donde una es mas ancha que la otra. El enchufe con conneccion a tierra tiene las mismas dos terminales mas una tercera en forma de punta que es la coneccion a tierra.

La terminal mas ancha o la tercera punta en estos enchufes es para su seguridad. Si el enchufe suministrado no encaja en su toma, consulte a un electricista para que reemplace el tomacorriente obsoleto. Servicio No intente reparar este producto usted mismo. Table of Contents Alarm Menu Left and Right Fields GigE Subnet Mask Menu GigE Default Gateway Menu The unit will process both highdefinition and standard-definition video services.

After the unit is properly configured, it is ready to receive authorization and control information from the satellite operator. No conversion is done between line and line video.

One VCT may be selected at a time.

When the programmer provides multiple audio choices, the audio pair can be selected. Programmers can tag audio channels with a language, and the receiver will select the audio material based on the language selected. Detachable connectors may ds ordered through Phoenix Contact.

  HYLES CHURCH MANUAL PDF

The five-pin part number is The seven-pin part number is Place each unit in a stable and level position within the rack and ensure that all front enclosure screws are tightened to 14 in-lbs.

If multiple units are installed in a rack assembly, the operator may choose to have a certification agency evaluate the condition of the rack. Mechanical Loading The mounting rack location should be secure and level to avoid hazardous instability to the equipment due to uneven loading or weight distribution within the rack.

Ambient Temperature When installing the 4640 within a closed or multi-unit rack, the ambient temperature may be greater than the ambient temperature within the room.

ARRIS DSR / DSR Commercial Integrated Receiver |

Always consider the affect that overloading circuits might have on over-current protection and supply wiring. To ensure that circuits are not overloaded, read the UL regulatory power label on top of the unit. Earth Ground Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit e.

The RF-IN antenna cable should only be connected while dsrr unit is properly grounded. The shield of the coaxial cable should be earthed in YP accordance with Article Battery Replacement Do not replace the lithium battery used in the unit. Instead, return the unit to a ARRIS authorized dst center for replacement with the same dwr equivalent type battery as recommended by the manufacturer.

Contact the programmer for this system information so that the desired services can be received.

Satellite Receiver Motorola DSR 4460

The unit will generate time-specific ad insertion cue tones, using messages the programmer can include in the encoded signal. The unit provides an alarm relay that can be used to signal an alarm condition. To indicate an alarm, the unit provides a short-circuit electrical connection between the NC and CM terminals and an open-circuit electrical connection between the NO and CM terminals.

With this configuration, the unit is able to signal an alarm for the loss of AC power. Plug the unit into a power source. Verify that the LCD screen is lit. Proceed with the installation using the front panel menus. The name of the current menu is always in the upper left corner of the screen for easy identification.

Note that the available keypad moves may change during the navigation between menu fields. These are called field labels and its setting dxr displayed directly below. Fields that can be changed have an arrow indicator just to the left of the field label.

The Signal LED is lit when the decoder recognizes a valid carrier signal. The Authorized LED is lit when the DigiCipher II signal LED is lit and either 1 the programmer has transmitted the access messages to allow the decoder to decrypt the signal, or 2 the signal is unencrypted or fixed key. The user may want to practice on a screen to become familiar with how the buttons work. Placing the blinking cursor on those arrows and using those arrow buttons will reveal each of the available choices for that field, one at a time.

Main Menu This menu is the top-level menu and can be navigated to from any other menu by pressing the ENTER button while the cursor is blinking next to the menu name. This menu allows the user to select any one of the five main menu groups: The unit allows the user to scroll only to menus that are in the same group. To scroll to ds menu that is in a different menu group, return to the main top-level menu and select the desired menu group.

  MAHAWANSA IN SINHALA PDF

The charts on the following pages show the menus organized into five main groups: This section describes in detail each of the Installation menus, fields, and options displayed on the LCD dst. Return to the main top-level menu and then select the installation menu group.

DSR Commercial Satellite Receiver | ARRIS

The unit displays the previously selected sub-menu. Use the Xpndr option in the Mode field and edit the Xpndr transponder field described on page 24for tuning such signals. For offset-frequency C-band, fractional transponders, or Ku-band satellite broadcasts, use the LFreq field in the Mode field described on page 24and directly edit the L-band frequency field. The unit does not actually require any distinction between C-band and Ku-band satellite signals in order to tune and acquire a compatible signal.

However, correct modulation information is necessary. Port 1 The Input field displays the input to which the decoder is currently tuned. It allows manual selection of Port 0 or Port 1 or the ASI input so that the unit can acquire the DigiCipher II system signal and automatically download network data required for operation.

To select the input: Unless changed, the unit displays Port 0. These three fields are not visible when ASI In is selected. The following screen prompts the user to confirm the selection and exit the field. Xpndr The Mode field allows selection of the frequency plan type for the satellite signal to which the unit is tuned.

If the application is a North American C-band satellite center frequency, select the transponder number in the Xpndr field. Otherwise, set this field to LFreq and also set the new field LFreq as described below.

There are two choices: Xpndr and L Freq. If Xpndr is selected, choose a transponder in the Xpndr field. The frequency in the LFreq field is set automatically and cannot be edited. Select a transponder frequency between and MHz in the LFreq field. This field is not available when the Mode field is set to LFreq.

This field allows selection of an initial satellite transponder number and can only be used if the Xpndr option in the Mode field is selected.

The Xpndr field cannot be edited if L Freq in the Mode field is selected. There are 24 transponder options, and when the desired transponder selection is displayed, press the ENTER button to confirm selection and move the cursor back up to the field label. If the Mode field is set to Xpndr, this field is set automatically and cannot be edited.

If the LFreq option in the Mode field is chosen, use this field, to directly tune the frequency. For those satellite carriers which are offset C-band or Ku-Banduse the L Freq option to enter the exact center frequency of a carrier, rather than using a nearbybut-not-exact C-band transponder center frequency.

Long-term frequency tracking is best if the user enters a precise carrier center frequency. Contact the programmer or network operator for details about the satellite, transponder, and frequencies being used.

If one frequency is identified as the root transponder, using this frequency may expedite the download process during installation.